Search results for "Dental Porcelain"

showing 10 items of 15 documents

Luting of ceramic crowns with a self-adhesive cement: Effect of contamination on marginal adaptation and fracture strength

2012

Objectives: This study evaluated the percentages of continuous margins (%CM) and fracture strength (FS) of crowns made out from blocs of leucite-reinforced ceramic (IPS Empress CAD) and luted with a representative self-adhesive cement (RelyX Unicem) under four contaminating agents: saliva, water, blood, a haemostatic solution containing aluminium chloride (pH= 0.8) and a control group with no contamination. Study Design: %CM at both tooth-cement (TC) and cement-crown (CC) interfaces were determined before and after a fatigue test consisting of 600’000 chewing loads and 1’500 temperature cycles changing from 5º C to 50º C. Load to fracture was recorded on fatigued specimens. Kruskal-Wallis t…

Dental Stress AnalysisSalivaAluminium chlorideDental CementsDentistryOdontologíaIn Vitro TechniquesDental porcelainFlexural strengthDental cementBiomaterials and Bioengineering in DentistryDentinmedicineHumansGeneral DentistryCementCrownsChemistrybusiness.industryContamination:CIENCIAS MÉDICAS [UNESCO]Dental PorcelainCiencias de la saludddc:617.6Resin Cementsmedicine.anatomical_structureOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASResearch-ArticleSurgerybusinessmedicine.drugMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

An 8-year prospective clinical investigation on the survival rate of feldspathic veneers: Influence of occlusal splint in patients with bruxism

2020

Este artículo se encuentra disponible en la siguiente URL: https://www.sciencedirect.com/science/article/abs/pii/S0300571220300944?via%3Dihub This is the pre-peer reviewed version of the following article: Faus-Matoses, V., Ruiz-Bell, E., Faus-Matoses, I., Özcan, M., Salvatore, S. & Faus-Llácer, VJ. An 8-year prospective clinical investigation on the survival rate of feldspathic veneers: influence of occlusal splint in patients with bruxism. Journal of Dentistry, vol. 99, art. 103352 (aug. 2020), which has been published in final form at https://doi.org/10.1016/j.jdent.2020.103352 Este es el pre-print del siguiente artículo: Faus-Matoses, V., Ruiz-Bell, E., Faus-Matoses, I., Özcan, M., Salv…

Bruxismo - Tratamiento.Ceramicsmedicine.medical_treatmentFérulas en odontología.Dentistry610 Medicine & healthOrthodontics.Bruxism - Treatment.10068 Clinic of Reconstructive Dentistry03 medical and health sciences0302 clinical medicineClinical investigationStatistical significanceOrtodoncia.Overall survivalHumansMedicineIn patientProspective Studies030212 general & internal medicineGeneral DentistrySurvival rateSplints Bite plane.business.industryOcclusal Splints030206 dentistryDental Porcelain3500 General DentistryFeldspathic ceramicSurvival RateDental Veneersstomatognathic diseasesCarillas de porcelana.BruxismDental ceramics.businessSplint (medicine)Journal of Dentistry
researchProduct

A facially driven complete-mouth rehabilitation with ultrathin CAD-CAM composite resin veneers for a patient with severe tooth wear: A minimally inva…

2020

Abstract The development of technologies that include face scanning and dental software has improved workflows in dentistry. Digital files make it possible to create a 3-dimensional virtual image of the patient that helps the clinician plan treatment and make decisions, reducing uncertainty and improving communication. This report describes the complete-mouth rehabilitation of a patient with severe tooth wear. The treatment adopted a minimal intervention approach, applying adhesive veneers in areas where the tooth structure was affected and used a computer-aided design and computer-aided manufacturing (CAD-CAM) workflow to prepare nanoceramic composite resin materials with a high filler loa…

Dental softwarebusiness.industryComputer scienceMouth RehabilitationIntervention approachDentistryCAD030206 dentistryComposite ResinsDental Porcelain03 medical and health sciences0302 clinical medicineDental porcelainstomatognathic systemDental Prosthesis DesignVirtual imageTooth wearDental Prosthesis DesignComputer-Aided DesignHumansTooth WearOral SurgeryMouth RehabilitationbusinessThe Journal of prosthetic dentistry
researchProduct

Fracture resistance and the mode of failure produced in metal-free crowns cemented onto zirconia abutments in dental implants.

2019

The purpose of the investigation was to analyze fracture resistance and mode of failure of zirconium oxide (zirconia) abutments placed on dental implants bearing crowns of different esthetic materials: zirconia, lithium disilicate (LDS), and nano-ceramic resin, for replacing single teeth in the anterior sector. Eighty implant-abutment-crown units were divided into four groups: Group T-MC (control): 20 metal-ceramic crowns cemented onto titanium abutments; Group Z-Z: 20 zirconia crowns on zirconia abutments; Group Z-LD: 20 lithium disilicate crowns on zirconia abutments; and Group Z-NCR: 20 nano-ceramic resin crowns on zirconia abutments. Specimens underwent a fatiguing process (dynamic load…

CeramicsTeethMedical Implantsmedicine.medical_treatmentDentistry02 engineering and technologyMaterial Fatigue0302 clinical medicineMaterials PhysicsMaterials TestingMedicine and Health SciencesCubic zirconiaDental Restoration FailureMaterialsDental CementumTitaniumProstheticsMultidisciplinaryCrownsPhysicsQRClassical Mechanics021001 nanoscience & nanotechnologyChemistryPhysical SciencesMedicineEngineering and TechnologyAnatomy0210 nano-technologyTitaniumResearch ArticleBiotechnologyChemical ElementsMaterials scienceScienceBiomaterial ImplantsMaterials ScienceAbutmentchemistry.chemical_elementBioengineeringLithiumCrown (dentistry)Anterior region03 medical and health sciencesmedicineHumansTitanium ImplantsDental ImplantsDamage Mechanicsbusiness.industryBiology and Life Sciences030206 dentistryDental PorcelainAssistive TechnologieschemistryMetal freeJawFracture (geology)Zirconium oxideMedical Devices and EquipmentZirconiumbusinessDigestive SystemHeadPloS one
researchProduct

Implant-supported metal-ceramic and resin-modified ceramic crowns: A 5-year prospective clinical study.

2018

Abstract Statement of problem Because of market demand for innovation, new restoration materials have been introduced without adequate testing; clinical failure may be the consequence, and clinical studies are needed. Purpose The purpose of this clinical study was to evaluate the biological and mechanical clinical behavior of implant-supported resin-modified ceramic crowns compared with that of metal-ceramic crowns. Material and methods Forty-two participants aged between 35 and 65 years received single implants in posterior edentulous sites. After the osseointegration period, half of the implants (selected randomly) (n=25) were restored with metal-ceramic crowns (MC group) and the other ha…

Ceramicsmedicine.medical_treatmentDentistryDental AbutmentsCrown (dentistry)Osseointegration03 medical and health sciences0302 clinical medicineDental porcelainstomatognathic systemDental AbutmentsmedicineCeramicDental Restoration FailureProspective StudiesSurvival rateDental ImplantsCrownsbusiness.industryDental prosthesis030206 dentistryDental PorcelainMetalsvisual_artvisual_art.visual_art_mediumImplantDental Prosthesis Implant-SupportedZirconiumOral SurgerybusinessThe Journal of prosthetic dentistry
researchProduct

A prospective evaluation of zirconia anterior partial fixed dental prostheses: Clinical results after seven years.

2014

Abstract Statement of problem Because of the high mechanical strength of zirconium dioxide, the metal in fixed partial prostheses can now be replaced. However, the material is susceptible to aging or hydrothermal degradation and to chipping of the feldspathic veneer. Purpose The purpose of this prospective study was to evaluate the survival (without failure) and success (survival without any complication or failure) rate and clinical efficacy of anterior zirconia partial fixed dental prostheses. Material and methods Twenty-seven anterior partial fixed dental prostheses of 3 to 6 units were fabricated. All participants were examined after 1 month and 6 months, then annually for 7 years. Resu…

Dental Restoration FailureAdultMaleSurface Propertiesmedicine.medical_treatmentDentistryDental CariesProsthesisProspective evaluationAnterior regionDental MaterialsRecurrencemedicineHumansDental Restoration FailureProspective StudiesProspective cohort studyDenture DesignSurvival rateAgedbusiness.industryPeriapical DiseasesMiddle AgedDental PorcelainDenture RetentionSurvival AnalysisDental VeneersTreatment OutcomeComputer-Aided DesignDenture Partial FixedVeneerFemaleZirconiumOral SurgerybusinessComplicationFollow-Up StudiesThe Journal of prosthetic dentistry
researchProduct

Influence of bruxism on survival of porcelain laminate veneers

2013

Objectives: This study aims to determine whether bruxism and the use of occlusal splints affect the survival of porcelain laminate veneers in patients treated with this technique. Material and Methods: Restorations were made in 70 patients, including 30 patients with some type of parafunc - tional habit. A total of 323 veneers were placed, 170 in patients with bruxism activity, and the remaining 153 in patients without it. A clinical examination determined the presence or absence of ceramic failure (cracks, frac - tures and debonding) of the restorations; these incidents were analyzed for association with bruxism and the use of splints. Results: Analysis of the ceramic failures showed that …

Dental Restoration FailureAdultMaleAdolescentDentistryOdontologíaMaterials testingOcclusal SplintsYoung AdultDental porcelainClinical and Experimental DentistryMaterials TestingMedicineHumansIn patientDental Restoration FailureGeneral DentistryAgedRetrospective StudiesOrthodonticsbusiness.industryResearchTreatment optionsOcclusal SplintsMiddle Aged:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludDental PorcelainSplintsstomatognathic diseasesDental VeneersOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASSurgeryBruxismFemalebusinessDental veneersMedicina Oral, Patología Oral y Cirugía Bucal
researchProduct

In vitro retentive strength of zirconium oxide ceramic crowns using different luting agents

2005

Statement of problem In contrast to gold crowns, in vitro determination of the retentive strength of all-ceramic crowns is more difficult because components allowing connection to testing apparatus are not as easily integrated into the all-ceramic material. Nevertheless, retentive strength data are crucial for obtaining information about the potential clinical performance of luting cements for all-ceramic restorations. Therefore, a new in vitro model was necessary to evaluate the retentive strength of all-ceramic crowns. Purpose The purpose of this in vitro study was to determine the retentive strength of 4 resin-cement systems, a compomer, a glass-ionomer cement, a resin-modified glass-ion…

Dental Stress AnalysisMaterials sciencemedicine.medical_treatmentDental CementsDentistryCrown (dentistry)Dental Prosthesis RetentionDental porcelainstomatognathic systemDental cementMaterials TestingmedicineHumansCeramicComposite materialCementationCementUniversal testing machineCrownsCompomersbusiness.industryLuting agentEpoxyDental PorcelainResin CementsGlass Ionomer Cementsvisual_artvisual_art.visual_art_mediumZirconiumOral SurgerybusinessThe Journal of Prosthetic Dentistry
researchProduct

Fracture Resistance of New Metal-Free Materials Used for CAD-CAM Fabrication of Partial Posterior Restorations

2020

Background and Objectives: To evaluate in vitro the fracture resistance and fracture type of computer-aided design and computer-aided manufacturing (CAD-CAM) materials. Materials and Methods: Discs were fabricated (10 &times

MolarCeramicschemistry.chemical_elementArticleStress (mechanics)Dental MaterialsGroup (periodic table)Tensile StrengthMaterials TestingDentinHumansMedicineCeramicComposite materialDental Restoration PermanentComputingMethodologies_COMPUTERGRAPHICSlcsh:R5-920business.industryWeibull modulusGeneral Medicinefracture resistance; resin nanoceramic; polymer-infiltrated ceramic network; lithium disilicate; zirconium-reinforced lithium silicatefracture resistancezirconium-reinforced lithium silicateDental PorcelainNanostructuresmedicine.anatomical_structurechemistrypolymer-infiltrated ceramic networkCase-Control Studiesvisual_artFracture (geology)visual_art.visual_art_mediumComputer-Aided DesignLithiumZirconiumresin nanoceramiclithium disilicatebusinesslcsh:Medicine (General)Medicina
researchProduct

Zirconia implant abutments: A review

2009

Objectives: An increasing aesthetic demand within developed populations conducted to the fabrication of metalfree restorations and to a wide use of ceramic materials, due to its excellent characteristics of biocompatibility and aesthetics. With the incessant increase of commercial labels involved in this technological advance, a review is imposed on ceramic abutments, specifically on zirconia. We made a search of articles of peer-reviewed Journals in PubMed/ Medline, crossing the terms ?Dental Abutments?, ?Dental Porcelain? and ?Zirconia?. The review was divided by subtopics: zirconia physical and mechanical properties, precision fit in the implant-abutment interface, zirconia abutments str…

Engineeringbusiness.industryProve itDentistryDental Abutments:CIENCIAS MÉDICAS [UNESCO]Ceramic abutmentsDental MaterialsDental porcelainDental Prosthesis DesignOtorhinolaryngologyDental AbutmentsUNESCO::CIENCIAS MÉDICASDental Prosthesis DesignHumansSurgeryCubic zirconiaZirconiumImplantTechnological advancebusinessGeneral DentistryMedicina Oral Patología Oral y Cirugia Bucal
researchProduct